Show simple item record

dc.contributor.authorBaz-Lomba, Jose Antonio
dc.contributor.authorHarman, Christopher
dc.contributor.authorReid, Malcolm
dc.contributor.authorThomas, Kevin V
dc.date.accessioned2018-11-02T08:03:54Z
dc.date.available2018-11-02T08:03:54Z
dc.date.issued2017
dc.identifier.citationWater Research. 2017, 121, 221-230.nb_NO
dc.identifier.issn0043-1354
dc.identifier.urihttp://hdl.handle.net/11250/2570711
dc.descriptionEmbargo until 20 May 2019.nb_NO
dc.description.abstractA passive sampling device, the Polar Organic Chemical Integrative Sampler (POCIS), was calibrated in-situ over a 4-week period in Oslo (Norway) for 10 illicit drugs and pharmaceuticals with the goal of developing an approach for monitoring long-term wastewater drug loads. The calibrations were performed in triplicate using three different overlapping calibration sets under changing environmental conditions that allowed the uncertainty of the sampling rates to be evaluated. All 10 compounds exhibited linear uptake kinetics and provided sampling rates of between 0.023 and 0.192 L d−1. POCIS were deployed for consecutive 2-week periods during 2012 and 2013 and the calculated time-weighted average (TWA) concentrations used to define different drug use trends. The relative uncertainty related to the POCIS data was approximately 40% and, except for citalopram, 85% of all the long-term measurements of pharmaceuticals were within the confidence interval levels calculated to evaluate the effects of changing environmental conditions on the TWA estimations. POCIS was demonstrated to be sufficiently robust to provide reliable annual drug use estimates with a smaller number of samplers (n = 24) than recommended for active sampling (n = 56) within an acceptable level of sample size related uncertainty < 10%. POCIS is demonstrated to be a valuable and reliable tool for the long-term monitoring of certain drugs and pharmaceuticals within a defined population.nb_NO
dc.language.isoengnb_NO
dc.publisherElseviernb_NO
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titlePassive sampling of wastewater as a tool for the long-term monitoring of community exposure: Illicit and prescription drug trends as a proof of conceptnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.source.pagenumber221-230nb_NO
dc.source.volume121nb_NO
dc.source.journalWater Research
dc.identifier.doi10.1016/j.watres.2017.05.041
dc.identifier.cristin1490728
dc.relation.projectEC/FP7/317205nb_NO


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal