Vis enkel innførsel

dc.contributor.authorBiałek, Agnieszka
dc.contributor.authorGoodman, Teresa
dc.contributor.authorWoolliams, Emma
dc.contributor.authorBrachmann, Johannes FS.
dc.contributor.authorSchwarzmaier, Thomas
dc.contributor.authorKuusk, Joel
dc.contributor.authorAnsko, Ilmar
dc.contributor.authorVabson, Viktor
dc.contributor.authorLau, Ian C.
dc.contributor.authorMacLellan, Christopher
dc.contributor.authorMarty, Sabine
dc.contributor.authorOndrusek, Michael
dc.contributor.authorServantes, William
dc.contributor.authorTaylor, Sarah
dc.contributor.authorDommelen, Ronnie Van
dc.contributor.authorBarnard, Andrew
dc.contributor.authorVellucci, Vincenzo
dc.contributor.authorBanks, Andrew C.
dc.contributor.authorFox, Nigel
dc.contributor.authorVendt, Riho
dc.contributor.authorDonlon, Craig
dc.contributor.authorCasal, Tânia
dc.date.accessioned2021-05-27T13:13:32Z
dc.date.available2021-05-27T13:13:32Z
dc.date.created2021-01-08T18:47:51Z
dc.date.issued2020
dc.identifier.citationRemote Sensing. 2020, 12 (14), 2220.en_US
dc.identifier.issn2072-4292
dc.identifier.urihttps://hdl.handle.net/11250/2756705
dc.description.abstractWe present the results from Verification of Reference Irradiance and Radiance Sources Laboratory Calibration Experiment Campaign. Ten international laboratories took part in the measurements. The spectral irradiance comparison included the measurements of the 1000 W tungsten halogen filament lamps in the spectral range of 350 nm–900 nm in the pilot laboratory. The radiance comparison took a form of round robin where each participant in turn received two transfer radiometers and did the radiance calibration in their own laboratory. The transfer radiometers have seven spectral bands covering the wavelength range from 400 nm–700 nm. The irradiance comparison results showed an agreement between all lamps within ±1.5%. The radiance comparison results presented higher than expected discrepancies at the level of ±4%. Additional investigation to determine the causes for these discrepancies identified them as a combination of the size-of-source effect and instrument effective field of view that affected some of the results.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleResults from Verification of Reference Irradiance and Radiance Sources Laboratory Calibration Experiment Campaignen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder2020 by the authorsen_US
dc.source.pagenumber18en_US
dc.source.volume12en_US
dc.source.journalRemote Sensingen_US
dc.source.issue14en_US
dc.identifier.doi10.3390/rs12142220
dc.identifier.cristin1868050
dc.relation.projectESA - den europeiske romfartsorganisasjonen: 4000117454en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal