Show simple item record

dc.contributor.authorSandvik, Morten
dc.contributor.authorWaaler, Thor Arnulf
dc.contributor.authorRundberget, Thomas
dc.contributor.authorAdolfsen, Pål
dc.contributor.authorBardal, Helge
dc.contributor.authorSandodden, Roar
dc.date.accessioned2019-06-27T06:55:38Z
dc.date.available2019-06-27T06:55:38Z
dc.date.created2017-12-12T12:15:49Z
dc.date.issued2018
dc.identifier.citationManagement of Biological Invasions. 2018, 9 (1), 59-65.nb_NO
dc.identifier.issn1989-8649
dc.identifier.urihttp://hdl.handle.net/11250/2602428
dc.description.abstractA fast, accurate and simple method using liquid chromatography (LC) with UV detection was used for the on-site determination of the piscicide rotenonein water during fish control treatments. Sample volumes of 10 to 40 µL were loaded onto a Waters XBridge™ C18 2.5 µm 3.0 x100 mm analytical column usinga mobile phase of water–acetonitrile (45:55) at a flow-rate of 0.5 mL/min. The method was evaluated using river and estuarine water spiked with rotenone(0.1–330 µg/L) and various preservation methods. The within-assay precision measured as relative standard deviation (RSD, n = 12) was 5.5 to 6.5% andthe between assay precision (RSD, n = 4) was 6.5 to 7.5%. The limit of quantification was 1 µg/L, below normal piscicidal treatment rates (5 to 200 µg/L)and regulatory limits (< 2 µg/L) generally considered safe. The analysis time was 6 min/sample allowing for real-time adjustment of rotenone dosages duringfish control treatments. The relatively small size (75×60×50 cm) of the LC system made it ideal for transportation and installation in remote treatment areas;it can be operated out of a small trailer in the field with electricity. Our studies indicate that the preservation of water samples with equal quantitiesof acetonitrile stabilizes rotenone indefinitely (> 170 days) if kept cool (4 °C) and in the dark. Although increased salinity decreased the recoveryof rotenone, sample filtration with Spin-X filter membranes negated the effect.nb_NO
dc.language.isoengnb_NO
dc.publisherRegional Euro-Asian Biological Invasions Centrenb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleFast and accurate on-site determination of rotenone in water during fish control treatments using liquid chromatographynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.rights.holder© 2018 The Author(s).nb_NO
dc.source.pagenumber59-65nb_NO
dc.source.volume9nb_NO
dc.source.journalManagement of Biological Invasionsnb_NO
dc.source.issue1nb_NO
dc.identifier.doi10.3391/mbi.2018.9.1.06
dc.identifier.cristin1526229
cristin.unitcode7464,30,21,0
cristin.unitnameMiljøkjemi
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal