Vis enkel innførsel

dc.contributor.authorGarmo, Øyvind Aaberg
dc.contributor.authorEscudero, Carlos
dc.contributor.otherGarmo, Øyvind Aaberg - Project manager
dc.date.accessioned2015-09-15T09:26:12Z
dc.date.accessioned2015-09-16T10:11:43Z
dc.date.available2015-09-15T09:26:12Z
dc.date.available2015-09-16T10:11:43Z
dc.date.issued2014
dc.identifier6634
dc.identifier.citationNIVA-rapport. 16 p. Norsk institutt for vannforskning, 2014nb_NO
dc.identifier.isbn978-82-577-6369-5
dc.identifier.issn1894-7948
dc.identifier.urihttp://hdl.handle.net/11250/300163
dc.descriptionnb_NO
dc.description.abstractBuilding of tunnels produces waste water that often is highly alkaline. Such water can be toxic to aquatic organisms, and pH should be lowered before discharge to recipient. A reactor tank was built to test the use carbon dioxide (CO2) gas for this purpose. Small scale experiments were conducted with three synthetic solutions prepared by diluting acids and bases, and one sample of tunnelling waste water from Gran, National road 4 (rv. 4). The pH decreased rapidly to pH 8.0 when CO2 gas was added to alkaline solutions. The rate of pH decrease was markedly slower below pH 7.0. The CO2 concentration was low (<40 mg/L) at pH values higher than 8.0, but increased rapidly as pH dropped below 8.0. Initially, the pH dropped faster and the CO2 concentrations increased faster at 4 °C than at 15 °C, but there were no clear differences when the experiments were terminated. The aqueous CO2 concentration in tunnelling waste water at pH 8.0 is probably not acutely toxic to fish, but can rapidly rise to toxic levels if pH declines further.nb_NO
dc.description.sponsorshipNorwegian Public Roads Administrationnb_NO
dc.language.isoengnb_NO
dc.publisherNorsk institutt for vannforskningnb_NO
dc.relation.ispartofseriesNIVA-rapport;6634
dc.rightsNavngivelse-Ikkekommersiell-DelPåSammeVilkår 3.0 Norge*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/no/*
dc.titleUsing carbon dioxide gas to lower the pH of tunnelling waste water – laboratory test and assessment of toxic potentialnb_NO
dc.typeResearch reportnb_NO
dc.date.updated2015-09-15T09:26:12Z
dc.rights.holderNorsk institutt for vannforskning / Norwegian institute for water research
dc.subject.nsiVDP::Matematikk og naturvitenskap: 400nb_NO
dc.subject.nsiVDP::Mathematics and natural scienses: 400nb_NO
dc.source.pagenumber16nb_NO
dc.identifier.cristin1264274
dc.subject.keywordKarbondioksid / Carbon dioxide
dc.subject.keywordPH justering / PH adjustment
dc.subject.keywordSamferdsel / Transport and communication
dc.subject.keywordTunneldrivevann / Tunnelling water
dc.relation.project13383nb_NO


Tilhørende fil(er)

Thumbnail
Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell-DelPåSammeVilkår 3.0 Norge
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell-DelPåSammeVilkår 3.0 Norge